Video storage (IMAGE PROCESSING
AND STORAGE)
Hard diskJaz drive, optional SVHS
VCR
Max. # of images (IMAGE PROCESSING
AND STORAGE)
1,000;8,000;36,000
Image matrix size (IMAGE PROCESSING
AND STORAGE)
680x 512 x 10
Last taken image hold (IMAGE
PROCESSING AND STORAGE)
Yes
Frame integration (IMAGE
PROCESSING AND STORAGE)
Yes
CASSETTE HOLDER SIZES (Focal spot
size, mm)
> 24 x 3024 x 30 cm
C-ARM
Free space, cm (in) (C-ARM)
76.2(30)
Depth, cm (in) (PA GANTRY)
66(26)
Orbital rotation, ° (C-ARM)
120with 30 overscan
Horizontal travel, cm (in) (C-ARM)
20(7.9)
Vertical movement, cm (in)(RADIATION DETECTOR)
43(16.9)
Panning motion, ° (C-ARM)
±10
Reverse position (C-ARM)
Yes POWER REQUIREMENTS
110/230 VAC, 15/8 A
H x W x D of C-arm frame, cm (in)
(IMAGE PROCESSING AND STORAGE)
169x 78 x 163 (66.5x 30.7 x 64.2)
WEIGHT, kg (lb) (DISPLAY)
245(539)
HARD COPY OPTION (MONITOR)
Multiformat camera, thermal
printer
@ 120 vac (Maximum output)
8mA @ 110 kVp
OTHER SPECIFICATIONS (AIR SUPPLY)
Single-platform design; point-and-
shoot; anatomically specific ABS modes. Meets requirements of CISPR, CSA, EU,
IEC, ISO, JIS, MedGV, NFPA, and UL.
FDA CLEARANCE (Interference
compensation)
Yes
CE MARK (MDD) (Interference
compensation)
Yes
OEC 7600 Compact "Rebuilt"
MODEL
7600Compact
+
@ 220 VAC
8mA @ 110 kVp
Heat capacity, hu (X-RAY TUBE)
76000
Cooling, hu/min (Maximum output)
19800
Focal spot size, mm (X-RAY TUBE)
Radiographic mode (Maximum output)
0.6-1.5
Fluoroscopic mode (Maximum output)
0.6
OPTIONAL FEATURES (PERFORMANCE)
Handheld patient annotation
keyboard, 44cm (17") monitor, thermal printer, laser aimer/localiz- er,
radiographic cassette holder, floppy disk
X-RAY TUBE ANODE
Stationary
Maximum output
IMAGE INTENSIFIER
Diameter, cm (in) (WHEELS)
23/15(9/6)
TV MONITOR SIZE, cm (in) (IMAGE
INTENSIFIER)
40.6(16)
Video storage (IMAGE PROCESSING
AND STORAGE)
Hard diskJaz drive, optional SVHS
VCR
Max. # of images (IMAGE PROCESSING
AND STORAGE)
1,000;8,000;36,000
Image matrix size (IMAGE PROCESSING
AND STORAGE)
680x 512 x 10
Last taken image hold (IMAGE
PROCESSING AND STORAGE)
Yes
Frame integration (IMAGE
PROCESSING AND STORAGE)
Yes
CASSETTE HOLDER SIZES (Focal spot
size, mm)
> 24 x 3024 x 30 cm
C-ARM
Free space, cm (in) (C-ARM)
76.2(30)
Depth, cm (in) (PA GANTRY)
66(26)
Orbital rotation, ° (C-ARM)
115with 25 overscan
Horizontal travel, cm (in) (C-ARM)19 (7.5)
Vertical movement, cm (in)(RADIATION DETECTOR)
42(16.5)
Panning motion, ° (C-ARM)
±10
Reverse position (C-ARM)
Yes POWER REQUIREMENTS
110/230 VAC, 15/8 A
H x W x D of C-arm frame, cm (in)
(IMAGE PROCESSING AND STORAGE)
169x 78 x 163 (66.5x 30.7 x 64.2)
WEIGHT, kg (lb) (DISPLAY)
245(539)
HARD COPY OPTION (MONITOR)
Multiformat camera, thermal
printer
@ 120 vac (Maximum output)
8mA @ 110 kVp
OTHER SPECIFICATIONS (AIR SUPPLY)
Single-platform design; point-and-
shoot; anatomically specific ABS modes. Meets requirements of CISPR, CSA, EU,
IEC, ISO, JIS, MedGV, NFPA, and UL.
FDA CLEARANCE (Interference
compensation)
Yes
CE MARK (MDD) (Interference
compensation)
Yes